WINSEN MH-441D-454B is an NDIR infrared gas sensor specifically designed for R454B refrigerant detection in the 0–5% vol range. It offers high precision, very fast response (<30 s), and excellent long-term durability. The sensor features both UART digital and analog (0.4–2 V) output, does not require O₂ calibration, and is suitable for direct replacement of catalytic cells.
Key Features
-
Detected gas: R454B refrigerant (CH₂F₂ and C₃H₂F₄ blend)
-
Detection range: 0–5% vol
-
Principle: NDIR (non-dispersive infrared spectroscopy)
-
Outputs: UART (3 V TTL), analog (0.4–2 V)
-
Power supply: 3.6–5 V DC (requires safety barrier)
-
Current consumption: <85 mA
-
Warm-up time: 3 minutes
-
Response time (T90): <30 s
-
Operating temperature: -20 to +60 °C
-
Humidity: 0–95% RH (non-condensing)
-
Ingress protection: IP54
-
Dimensions: diameter 20 mm × length 22.4 mm
-
Lifespan: >5 years
Applications